D-PST-MN-A-24 Latest Exam Book, D-PST-MN-A-24 Test Questions Fee
We have three formats of study materials for your leaning as convenient as possible. Our Storage Administrator question torrent can simulate the real operation test environment to help you pass this test. You just need to choose suitable version of our D-PST-MN-A-24 guide question you want, fill right email then pay by credit card. It only needs several minutes later that you will receive products via email. After your purchase, 7*24*365 Day Online Intimate Service of D-PST-MN-A-24 question torrent is waiting for you. We believe that you don’t encounter failures anytime you want to learn our D-PST-MN-A-24 guide torrent.
EMC D-PST-MN-A-24 Exam Syllabus Topics:
Topic
Details
Topic 1
Topic 2
Topic 3
>> D-PST-MN-A-24 Latest Exam Book <<
D-PST-MN-A-24 Test Questions Fee | New D-PST-MN-A-24 Test Fee
Each of the DumpsTests EMC D-PST-MN-A-24 exam dumps formats excels in its way and carries actual Dell PowerStore Maintenance Achievement (D-PST-MN-A-24) exam questions for optimal preparation. All of these Dell PowerStore Maintenance Achievement (D-PST-MN-A-24) practice question formats are easy to use and extremely convenient such that even newbies find them simple.
EMC Dell PowerStore Maintenance Achievement Sample Questions (Q35-Q40):
NEW QUESTION # 35
While on-site installing a Dell EMC PowerStore system, the node A and B embedded module fault LEDs are alternating blue and amber (blue for 3 seconds). What does this indicate?
Answer: C
Explanation:
When the node A and B embedded module fault LEDs on a Dell EMC PowerStore system are alternating between blue and amber, with the blue LED illuminated for 3 seconds, it indicates that the system is not initialized1. This LED behavior is part of the system's design to communicate its current state to the user or technician on-site.
The initialization process is a critical step during the installation of a PowerStore system. It involves setting up the system's configuration, including network settings, storage pools, and other essential parameters. Until this process is completed, the system cannot perform storage operations or host any virtual machines.
To resolve this and initialize the system, the following steps should be taken:
Connect to the system through the PowerStore Manager using a supported web browser.
Complete the Initial Configuration Wizard (ICW), which guides you through the necessary steps to initialize the system.
Once the ICW is completed, the system will finalize its configuration and the LEDs should reflect a normal operational state.
For more detailed guidance on the initialization process and understanding the LED indicators, refer to the Dell PowerStore Installation and Service Guide2. This document provides comprehensive instructions on installing and configuring the PowerStore system, ensuring it is ready for use.
NEW QUESTION # 36
How many fan module failures can a node tolerate?
Answer: A
Explanation:
A Dell EMC PowerStore node can tolerate one fan module failure. The system is designed with redundancy to ensure that if a single fan module fails, the remaining fan modules can compensate for the loss and maintain proper cooling to prevent overheating1. The system will increase the speed of the remaining fans to ensure continued cooling.
When a fan module failure occurs, the system will generate an alert to notify the administrator of the fault. The administrator should then take the following steps:
Acknowledge the alert in the PowerStore Manager.
Plan for the replacement of the faulted fan module as soon as possible to restore full redundancy.
Follow the replacement procedures as outlined in the Dell PowerStore Installation and Service Guide1.
It is important to address fan module failures promptly to ensure the long-term health and performance of the PowerStore system. The increased fan speed is a temporary measure to maintain operations until the faulted fan module can be replaced.
NEW QUESTION # 37
What does the output of the PSTCLI command "nas_server show" display from a Dell EMC PowerStore T?
Answer: C
Explanation:
The nas_server show command in the Dell EMC PowerStore T environment is used to display the status of NAS servers. The output of this command will indicate whether NAS servers are present and if so, their current state, which can be either 'Started' or 'Degraded'. This information is crucial for administrators to quickly assess the health and operational status of the NAS servers.
The command does not provide memory utilization, thread count, or SIDs of SMB NAS servers joined to the AD domain. Instead, it focuses on the operational status of the NAS servers, which is a critical aspect of system maintenance and troubleshooting.
For detailed information on the usage of the nas_server show command and interpreting its output, administrators should refer to the Dell PowerStore CLI User Guide1. This guide provides comprehensive instructions and examples for using the PowerStore CLI to manage and monitor the storage system effectively. It is essential to follow the official documentation to ensure accurate and reliable system management.
NEW QUESTION # 38
A Storage Administrator ran a PSTCLI command on a Linux host. The error " -bash: pstcli: command not found" appears. How is the problem resolved?
Answer: C
Explanation:
When the error "-bash: pstcli: command not found" appears after running a PSTCLI command on a Linux host, it typically means that the shell cannot locate the pstcli executable in the directories listed in the PATH environment variable. To resolve this issue, the installation directory of pstcli needs to be added to the PATH variable. This can be done by editing the shell initialization file (such as .bashrc or .bash_profile for Bash shell) and appending the installation directory to the PATH variable.
Here are the steps to resolve the problem:
Locate the installation directory of PSTCLI. If you followed the default installation, it should be in /opt/dellemc/pstcli-version/bin/.
Open the shell initialization file in a text editor. For example, if using Bash, you might edit ~/.bashrc or ~/.bash_profile.
Add the following line to the file: export PATH=$PATH:/opt/dellemc/pstcli-version/bin/. Replace /opt/dellemc/pstcli-version/bin/ with the actual installation directory if it is different.
Save the file and reload the shell configuration by running source ~/.bashrc or source ~/.bash_profile, or simply close and reopen the terminal.
Verify that pstcli can be found by running echo $PATH and ensuring the directory is listed.
Try running the pstcli command again to confirm that the issue is resolved.
By adding the PSTCLI installation directory to the PATH variable, the shell will be able to locate the pstcli executable when the command is run1. It is important to ensure that the PATH variable is correctly set to include all necessary directories for command-line tools to function properly. If the issue persists, it may be necessary to check the installation of PSTCLI or consult the Dell EMC PowerStore documentation for further troubleshooting steps1.
NEW QUESTION # 39
What describes the SAS cabling when adding an expansion enclosure to a Dell EMC PowerStore, for each node and expansion enclosure side?
Answer: B
Explanation:
The correct description of the SAS cabling when adding an expansion enclosure to a Dell EMC PowerStore, for each node and expansion enclosure side, is Option D: SAS cabling goes from existing A ports to new B ports. At the last enclosure, SAS cabling returns from the A ports to the alternate node's B ports.
When adding a SAS expansion enclosure to a Dell EMC PowerStore system, the cabling must be done in a specific manner to ensure proper connectivity and performance.
The SAS cabling should start from the existing A ports on the base enclosure and connect to the new B ports on the expansion enclosure1.
At the last expansion enclosure in the chain, the SAS cabling should return from the A ports back to the B ports on the alternate node1.
This cabling method ensures that each node is connected to each expansion enclosure and that the enclosures are daisy-chained correctly for optimal performance and redundancy1.
For detailed cabling instructions and diagrams, it is recommended to consult the Dell PowerStore Installation and Service Guide or contact Dell EMC support for assistance.
NEW QUESTION # 40
......
DumpsTests is growing faster and many people find that obtaining a certificate has outstanding advantage over other peer, especially for promotion or applying for a large company. DumpsTests helps fresh people enter into this area and help experienced workers have good opportunities for further development. Thus our passing rate of best D-PST-MN-A-24 Study Guide materials is nearly highest in this area. That's why we grows rapidly recent years and soon become the pioneer in D-PST-MN-A-24 qualification certificate learning guide providers. Our D-PST-MN-A-24 study guide will be your best choice to help you clear exam certainly.
D-PST-MN-A-24 Test Questions Fee: https://www.dumpstests.com/D-PST-MN-A-24-latest-test-dumps.html